Solar Charge Controller

  • 10A 20A 30A  solar charge controller 12v/24v auto detect
  • 10A 20A 30A  solar charge controller 12v/24v auto detect
  • 10A 20A 30A  solar charge controller 12v/24v auto detect
10A 20A 30A  solar charge controller 12v/24v auto detect10A 20A 30A  solar charge controller 12v/24v auto detect10A 20A 30A  solar charge controller 12v/24v auto detect

10A 20A 30A solar charge controller 12v/24v auto detect

  • 1.charging mode: PWM
  • 2.light control+time control
  • 3.protection grade:IP68
  • 5.charging voltage:12v/24v
  • Product description: 10A 20A 30A solar charge controller 12v/24v auto detect
  • INQUIRY


Tech Data

Model

5A

10A

15A

20A

30A

Rated Charge Current

5A

10A

15A

20A

30A

Rated Load Current

5A

10A

15A

20A

30A

System Voltage

24V/12V AUTO

Over load, short circuit protection

1.25 times by rated current, 60 seconds, 1.5 times by rated current,5 seconds--- overload protection; ≥3 times by rated current--- short circuit protection

No- load Loss

≤6mA

Charge Circuit Voltage Drop

≤0.26V

Discharge Circuit Voltage Drop

≤0.15V

Over Voltage Protection

17V, ×2/24V

Working Temperature

Industrial Grade: -35-+55 (Suffix I )

Increase Charge Voltage

14.6V, ×2/24V (10 min when discharging)

Direct Charge Voltage

14.4V, ×2/24V (10 min )

Float Charge Voltage

13.6V, ×2/24V (till come down to charging recovery voltage)

Charge Recovery Voltage

13.2V, ×2/24V

Temperature Compensation

-5mv//2v

Under Voltage

12.0V, ×2/24V

Over discharge Voltage

11.1V, ×2/24V

Over Discharge Recovery Voltage

12.6V, ×2/24V

Control Mode

PWM

Net Weight

160~200g

Part Three, Installation and application


1, To fasten the controller well,The outside size 140*90mm The hole size 133.5*70mm


2, The cable: to advise to use multi-strand insulated copper wire, to assure the cable can meet the installation needs, than keep it as short as possible, so that to reduce extra power consumption. The cable should no bigger than 4A/MM2, to strip 5MM for the controller side.


3, To connect the cable to the controller battery point first, than to connect the cable to the battery, pay attention to +/- pole, don’t put wrong connection. If it is correct, the LED-2 will be bright, to press the button to check it. Otherwise, to check the cable connection. In case of reverse, insurance and controllers will not burn any component damage. Fuse inside the controller itself only as a final short circuit protection circuit is damaged.


4, To connect the cable to the controller PV point, than to connect the cable to the PV, Pay attention to +/- pole, don’t put wrong connection. If there is sunshine, The LED-1 will be bright, otherwise, to check the cable connection.


5, To connect the load cable to the controller load point, Pay attention to +/- pole, don’t put wrong connection. Otherwise, it may burn the load.