Tech Data
Model |
5A |
10A |
15A |
20A |
30A |
Rated Charge Current |
5A |
10A |
15A |
20A |
30A |
Rated Load Current |
5A |
10A |
15A |
20A |
30A |
System Voltage |
24V/12V AUTO |
||||
Over load, short circuit protection |
1.25 times by rated current, 60 seconds, 1.5 times by rated current,5 seconds--- overload protection; ≥3 times by rated current--- short circuit protection |
||||
No- load Loss |
≤6mA |
||||
Charge Circuit Voltage Drop |
≤0.26V |
||||
Discharge Circuit Voltage Drop |
≤0.15V |
||||
Over Voltage Protection |
17V, ×2/24V |
||||
Working Temperature |
Industrial Grade: -35℃-+55℃ (Suffix I ) |
||||
Increase Charge Voltage |
14.6V, ×2/24V (10 min when discharging) |
||||
Direct Charge Voltage |
14.4V, ×2/24V (10 min ) |
||||
Float Charge Voltage |
13.6V, ×2/24V (till come down to charging recovery voltage) |
||||
Charge Recovery Voltage |
13.2V, ×2/24V |
||||
Temperature Compensation |
-5mv/℃/2v |
||||
Under Voltage |
12.0V, ×2/24V |
||||
Over discharge Voltage |
11.1V, ×2/24V |
||||
Over Discharge Recovery Voltage |
12.6V, ×2/24V |
||||
Control Mode |
PWM |
||||
Net Weight |
160~200g |
Part Three, Installation and application
1, To fasten the controller well,The outside size 140*90mm The hole size 133.5*70mm
2, The cable: to advise to use multi-strand insulated copper wire, to assure the cable can meet the installation needs, than keep it as short as possible, so that to reduce extra power consumption. The cable should no bigger than 4A/MM2, to strip 5MM for the controller side.
3, To connect the cable to the controller battery point first, than to connect the cable to the battery, pay attention to +/- pole, don’t put wrong connection. If it is correct, the LED-2 will be bright, to press the button to check it. Otherwise, to check the cable connection. In case of reverse, insurance and controllers will not burn any component damage. Fuse inside the controller itself only as a final short circuit protection circuit is damaged.
4, To connect the cable to the controller PV point, than to connect the cable to the PV, Pay attention to +/- pole, don’t put wrong connection. If there is sunshine, The LED-1 will be bright, otherwise, to check the cable connection.
5, To connect the load cable to the controller load point, Pay attention to +/- pole, don’t put wrong connection. Otherwise, it may burn the load.